Brictec KTB Fired Brick Plant Production Line Project – Tunnel Dryer Nearing Completion of Main Structure Construction

From the perspective of the overall plant process, the drying chamber's cycle time directly impacts the efficiency of both upstream and downstream stages: brick setting speed must match the drying cycle, and the firing kiln must await dry green bricks for charging. The intelligent drying system, through precise hot-air circulation and moisture-exhaust control, shortens the drying cycle while ensuring green-brick quality, enabling the four main stages—forming, setting, drying, and firing—to operate in seamless coordination and maximize total plant capacity.

Brictec KTB Fired Brick Plant Production Line Project1.jpg

The Brictec KTB project adopts a tunnel‑dryer process, with the tunnel dryer and tunnel kiln laid out identically. Kiln cars carrying green bricks travel continuously at a uniform speed, with automated systems matched to setting and loading/unloading equipment. Meanwhile, it can accommodate EPC turnkey lines with daily outputs of 200–1,200 tons, featuring gradient temperature control, cyclone hot‑air circulation, and stable mass production. This dryer is suitable for large‑scale fully automatic fired brick production lines and is universally applicable to hollow, perforated, and paving bricks.

Brictec KTB Fired Brick Plant Production Line Project2.jpg

Drying Chamber Thermal Calculation Sheet for KTB Project:

No.ItemValueUnitRemarks
1Product400×200×200mm—
2Output46,000pieces—
3Finished product14.42kg—
4Dried green brick16.58kg—
5Wet green brick19.46kg—
6Hourly moisture removal during drying5,520kg—
7Dryer unit energy consumption950kcal/kg—
8Dryer supply air temperature130℃—
9Dryer exhaust air temperature40℃—
10Hourly heat demand of dryer5,244,000kcal—
11Required air volume for dryer277,228m³—
12Supply hot‑air fan air volume326,150m³5 fans
13Dryer exhaust air volume215,316m³—
14Exhaust fan air volume66,495m³4 fans
15Number of cyclones180——


Construction progress photos taken in August 2026:

Brictec KTB Fired Brick Plant Production Line Project3.jpg

Author: Brictec Weijiangfei
Technical Engineering: Ms. Han
Editor: Wendy Luo
Copyright: Xi'an Brictec engineering Co., Ltd. 

Previous:Project Update | Brictec MUSK Project Engineering Progress | Drying Chamber

Next:Brictec MUSK Production Line Project July Site Construction Progress Report

News Recommendation

  • 1
  • 2
  • 3

International Business:+86 181-8262-2677   
Domestic Business:+86 156-1925-3978

Email address:info@brictec.com      Website:www. brictec.com

Address:Room B501, R&D Building, ZTE Industrial Park, No. 10 Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China. Click on Map

Brictec Technology Copyright@2011-2019 Shaanxi ICP Record No. 19011661

Search

Your Keywords

陕公网安备 61019002002413号